Source: Intuition-6 Brochure, Pages: 5–6The Intuition-6 model code specifies the controller configuration, relay types, sensor inputs, and included sensors. Use this guide to build the correct model number for your application.
Select sensor codes based on your base model. Choose the specified number of characters in alphabetical order, with “N” (no sensor) last if fewer sensors are needed.
WCT6 Sensors
WDS6 Sensors
WPH6 Sensors
WBL6 Sensors
WCN6 Sensors
WPD6 Sensors
Choose 4 codes in alphabetical order (except N last)
Code
Sensor
A
Graphite contacting conductivity
B
316SS contacting conductivity
C
Electrodeless conductivity
D
High pressure contacting conductivity
E
Graphite conductivity for makeup water (threaded adapter)
F
Flat surface WEL pH, no ATC
G
High pressure pH, no ATC
H
Rod style WEL ORP
I
Flat surface WEL ORP
J
High pressure ORP
K
Free chlorine, 20 ppm, extended pH range membrane
L
Chlorine dioxide 0-20 ppm membrane
M
Little Dipper 2, 0-200 ppb PTSA (analog)
N
No sensor
P
Pyxis PTSA (analog)
S
Disinfection membrane, no sensor
T
Pyxis Tagged Polymer (analog)
U
Pyxis PTSA + Tagged Polymer (2 analog)
V
Flat surface WEL pH, 4-20 mA (analog)
W
Rod style WEL ORP, 4-20 mA (analog)
X
Flat surface WEL ORP, 4-20 mA (analog)
Dipper, Pyxis, chlorine, ClO₂, and disinfection sensors are not available with submersion mounting. Electrodeless conductivity requires “A” sensor input board.
Choose 2 codes in alphabetical order
Code
Sensor
A
Free chlorine, 0-20 ppm
B
Chlorine dioxide, 0-20 ppm
C
Ozone, 0-20 ppm
D
Peracetic acid (PAA), 0-2000 ppm
E
Extended pH range free chlorine, 0-20 ppm
F
Total chlorine, 0-20 ppm
G
Hydrogen peroxide, 0-2000 ppm
H
Stabilized bromine, 0-20 ppm
I
Chlorite, 0-2 ppm
J
Chlorine (absence detection), 0-2 ppm
N
No sensor
X
Disinfection manifold + pH/ORP/conductivity tee
Choose 4 codes in alphabetical order
Code
Sensor
A
External pH/ORP preamplifier, no sensor
B
Flat surface WEL pH with Pt1000 ATC
C
Flat surface WEL pH, no ATC
D
Rod style WEL ORP
E
Flat surface WEL ORP
F
Flat surface WEL pH, 4-20 mA
G
Rod style WEL ORP, 4-20 mA
H
Flat surface WEL ORP, 4-20 mA
N
No sensor
X
Dual low pressure manifold
Choose 2 codes in alphabetical order
Code
Sensor
A
Boiler sensor with ATC, 250 psi, 1.0 cell, 20 ft cable
B
Boiler sensor without ATC, 250 psi, 1.0 cell, 20 ft cable
C
Condensate sensor with ATC, 200 psi, 0.1 cell, 10 ft cable
D
Boiler sensor with ATC, 250 psi, 10 cell, 20 ft cable
N
No sensor
Choose 2 codes in alphabetical order
Code
Sensor
A
PEEK electrodeless conductivity, 20 ft cable
B
CPVC electrodeless conductivity, 20 ft cable
C
Contacting conductivity, 1.0 cell, 100 psi, 10 ft
D
Contacting conductivity, 0.1 cell, 100 psi, 10 ft
E
Contacting conductivity, 10.0 cell, 100 psi, 10 ft
F
Contacting conductivity, 0.01 cell, 100 psi, 10 ft
G
Contacting conductivity, 1.0 cell, 200 psi, 10 ft
H
Contacting conductivity, 0.1 cell, 200 psi, 10 ft
I
Contacting conductivity, 10.0 cell, 200 psi, 10 ft
J
Contacting conductivity, 0.01 cell, 200 psi, 10 ft
N
No sensor
Electrodeless sensors (A, B) require “A” sensor input board — not compatible with “C” combination board.