Skip to main content

DICE Dosing Module

Source: DICE IOM Manual V12E, Pages: 1, 4–7 The DICE (Dosing Integrated Chemical Equipment) is a patented all-in-one chemical dosing solution from Meunier Technologies. It integrates all essential dosing system components—back pressure valve, pressure relief valve, pressure gauge with isolator, ball valves, and bleed valve—into a single chemical-resistant block.
DICE module showing integrated components: ball valves, back pressure valve, pressure relief valve, pressure gauge, and bleed valve

Key Features

  • 7× fewer joints than conventional systems
  • No threaded or glued connections on the pressurized side
  • 50% smaller footprint than traditional skid systems
  • Vertical configuration prevents gas lock conditions
  • Minimal internal volume (5 in³ for 1/2”, 12 in³ for 1”) for faster priming

Models

Designed for suction lift applications where the pump draws chemical from a tank located below the dosing system.
SpecificationValue
Size1/2” only
Ball valves3 (injection, calibration column, evacuation)
Auxiliary ports3
Max pressure250 psi
Max flow rate60 LPH (16 GPH)
The DM model’s additional ball valve and auxiliary port make it more versatile. Many facilities standardize on DM to simplify training and spare parts inventory.

Integrated Components

ComponentFunction
Back Pressure ValveMaintains constant discharge pressure; prevents siphoning
Pressure Relief ValveProtects system from overpressure conditions
Pressure Gauge with IsolatorDisplays system pressure; isolator protects gauge from chemical attack
Ball ValvesControl flow for injection, calibration, and evacuation
Bleed ValveAssists pump priming; enables depressurization

Applications

DICE modules are installed in over 1,800 locations worldwide:
  • Water and wastewater treatment
  • Industrial process chemical dosing
  • Sodium hypochlorite disinfection
  • pH adjustment (sodium hydroxide, acids)
  • Polymer and coagulant feed systems

What’s in the Box

  • DICE dosing module (factory tested)
  • Three mounting washers
  • Installation, Operation and Maintenance Manual (IOM)
  • Purchased spare parts and connectors
Do not adjust factory-preset back pressure and pressure relief valves. Factory-set valves are labeled with the target pressure.

Sources

DICE IOM Manual V12E